Foundry

Allowable Operating Pressure

Technical solutions

Allowable operating pressures

PAM pipelines are designed to withstand high pressures, generally much greater than the values usually encountered in the networks. This is justified by the need to withstand the numerous stresses on the pipelines during installation, but also and above all, over the years.

Pipeline design calculation

When choosing a pipeline component, it is essential to ensure that the three inequalities opposite are respected.

DP = Design pressure in steady state,
MDP= Maximum design pressure,
STP = System test pressure.

Safety factor

The pressures indicated in the following tables were produced using high safety factors which take into account not only the forces due to the internal pressure but also numerous other sometimes accidental stresses on the pipelines during installation and when they are in service.

For a pipe, the allowable operating pressure (PFA) is calculated with a safety factor of:
– 3 with respect to the minimum tensile strength,
– approximately 2 with respect to the minimum yield strength.

See also

Safety factor of ductile iron pipelines.
If protection devices have not been provided, ductile iron pipes have a safety coefficient which is often useful when faced with accidental pressure surges.
Hydraulic thrust in ductile cast iron pipelines